{"id":10982,"date":"2026-11-02T08:36:42","date_gmt":"2026-11-02T08:36:42","guid":{"rendered":"https:\/\/shenyingfireglass.com\/double-glazed-insulated-fire-rated-glass-dgu-igu-guide\/"},"modified":"2026-11-02T08:36:42","modified_gmt":"2026-11-02T08:36:42","slug":"guide-sur-le-vitrage-isolant-a-double-vitrage-resistant-au-feu-dgu-igu","status":"publish","type":"post","link":"https:\/\/shenyingfireglass.com\/fr\/guide-sur-le-vitrage-isolant-a-double-vitrage-resistant-au-feu-dgu-igu\/","title":{"rendered":"Guide architectural sur le verre isolant \u00e0 double vitrage r\u00e9sistant au feu (DGU \/ IGU) : allier efficacit\u00e9 \u00e9nerg\u00e9tique, rev\u00eatements \u00e0 faible \u00e9missivit\u00e9 et protection anti-incendie certifi\u00e9e de classe EI"},"content":{"rendered":"<p class=\"lead\" style=\"font-size: 1.15em; line-height: 1.8; color: #333;\">In contemporary high-rise and commercial architecture, building envelopes face two stringent and often competing regulatory demands: <strong>maximizing building energy efficiency (LEED, BREEAM, ASHRAE 90.1, EN ISO 10077)<\/strong> and <strong>ensuring uncompromised passive fire containment (EN 1364, UL 263, ASTM E119, BS 476)<\/strong>.<\/p>\n<p style=\"font-size: 1.05em; line-height: 1.8; color: #333;\">Standard insulating glass units (IGU \/ DGU) provide excellent thermal insulation and solar heat gain control, but shatter within minutes under the extreme thermal stresses of a structural fire. Conversely, conventional single-pane fire-rated glass provides fire integrity but lacks adequate acoustic dampening, condensation resistance, and thermal insulation (U-values typically exceeding 5.0 W\/m&sup2;K).<\/p>\n<p style=\"font-size: 1.05em; line-height: 1.8; color: #333;\"><strong>Double Glazed Insulated Fire-Rated Glass Units (Fire-Rated DGU \/ IGU \/ \u53cc\u5c42\u4e2d\u7a7a\u9694\u70ed\u8282\u80fd\u9632\u706b\u73bb\u7483)<\/strong> deliver the ultimate architectural synergy. By combining advanced magnetron sputtering Low-E coatings, warm-edge gas-filled cavities, and certified Class EI \/ Class E fire-resistant glass panes, these composite assemblies achieve low thermal transmittance (U-values down to 1.1 W\/m&sup2;K) while stopping convective flames, toxic gases, and radiant heat for 30, 60, 90, and 120 minutes.<\/p>\n<figure style=\"margin: 35px 0; text-align: center;\">\n  <img decoding=\"async\" src=\"https:\/\/shenyingfireglass.com\/wp-content\/uploads\/2026\/11\/img-mvz05kwc-9254006c.png\" alt=\"Double Glazed Insulated Fire-Rated Glass Unit (DGU \/ IGU) Architectural Cross-Section - Jinan Shenying\" style=\"max-width: 100%; height: auto; border-radius: 8px; box-shadow: 0 6px 20px rgba(0,0,0,0.12); border: 1px solid #e2e8f0;\" \/><figcaption style=\"margin-top: 12px; font-size: 0.92em; color: #64748b; font-style: italic;\">Figure 1: Cross-sectional architectural engineering view of Jinan Shenying Double-Glazed Insulated Fire-Rated Glass Unit (DGU\/IGU), highlighting the outer Low-E tempered pane, warm-edge argon-filled spacer cavity, and inner Class EI nano-silicon fire barrier.<\/figcaption><\/figure>\n<hr style=\"border: 0; height: 1px; background: #e2e8f0; margin: 35px 0;\" \/>\n<h2 style=\"color: #0f172a; margin-top: 30px;\">1. Multi-Layer Structural Architecture of Fire-Rated DGU \/ IGU Systems<\/h2>\n<p style=\"line-height: 1.8; color: #333;\">A high-performance fire-rated insulating glass unit is a precision-engineered composite assembly designed to withstand differential thermal expansions, dynamic wind pressures, and intense furnace heat loads:<\/p>\n<ol style=\"line-height: 1.8; color: #333; padding-left: 20px;\">\n<li style=\"margin-bottom: 12px;\"><strong>Outer Glazing Pane (Weather &amp; Energy Barrier):<\/strong> High-performance Low-E tempered glass (Single, Double, or Triple Silver coatings) on surface #2, or laminated solar control safety glass. Provides solar heat reduction (low SHGC \/ g-value), UV shielding, and primary resistance against exterior wind load, rain, and impact.<\/li>\n<li style=\"margin-bottom: 12px;\"><strong>Hermetically Sealed Gas Cavity (12mm &#8211; 20mm):<\/strong> Filled with &ge;90% high-purity Argon (Ar) gas for optimized thermal and acoustic insulation. Spacers utilize stainless steel or composite warm-edge bars with 3A molecular sieve desiccant to prevent condensation. Sealed with primary Polyisobutylene (PIB) and high-modulus, fire-resistant secondary structural silicone.<\/li>\n<li style=\"margin-bottom: 12px;\"><strong>Inner Glazing Pane (Certified Fire Safety Barrier):<\/strong> Features Class EI nano-silicon intumescent composite fire glass (expanding into a rigid ceramic thermal insulation blanket during fire exposure) or monolithic high-stress chemical-tempered fire glass for Class E\/EW applications.<\/li>\n<\/ol>\n<div style=\"background-color: #f8fafc; border: 1px solid #cbd5e1; border-left: 4px solid #0284c7; padding: 18px 24px; margin: 25px 0; border-radius: 4px; font-family: monospace; font-size: 0.95em; color: #334155; overflow-x: auto;\">\n<strong>[HIGH-PERFORMANCE FIRE-RATED DGU \/ IGU ARCHITECTURAL PROFILE]<\/strong><br \/>\n+ [ Exterior Pane ]: 6mm &#8211; 10mm Ultra-Clear Low-Iron Low-E Tempered Glass (Pos #2)<br \/>\n+ [ Insulated Cavity ]: 12A \/ 16A \/ 20A Argon Gas (&ge;90%) + Warm-Edge Spacer<br \/>\n+ [ Fire Barrier Pane ]: Class EI Nano-Silicon Composite (EI30, EI60, EI90, EI120) OR Class E\/EW Monolithic<br \/>\n+ [ Perimeter Seal ]: Dual Primary PIB Vapor Seal + Fire-Rated Structural Silicone Sealant\n<\/div>\n<hr style=\"border: 0; height: 1px; background: #e2e8f0; margin: 35px 0;\" \/>\n<h2 style=\"color: #0f172a; margin-top: 30px;\">2. Technical Specifications &amp; Performance Matrix<\/h2>\n<p style=\"line-height: 1.8; color: #333;\">Jinan Shenying designs and custom-manufactures fire-rated DGU \/ IGU systems according to project-specific climatic, acoustic, and fire resistance criteria:<\/p>\n<div style=\"overflow-x: auto; margin: 25px 0;\">\n<table style=\"width:100%; border-collapse:collapse; text-align:left; font-size: 0.95em;\">\n<thead>\n<tr style=\"background-color:#0f172a; color:#ffffff;\">\n<th style=\"padding:14px; border:1px solid #334155;\">Glazing Parameter<\/th>\n<th style=\"padding:14px; border:1px solid #334155;\">Standard IGU (Non-Fire)<\/th>\n<th style=\"padding:14px; border:1px solid #334155;\">DGU Class E60<\/th>\n<th style=\"padding:14px; border:1px solid #334155;\">DGU Class EI30<\/th>\n<th style=\"padding:14px; border:1px solid #334155;\">DGU Class EI60<\/th>\n<th style=\"padding:14px; border:1px solid #334155;\">DGU Class EI120<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr style=\"background-color:#ffffff;\">\n<td style=\"padding:12px; border:1px solid #e2e8f0;\"><strong>Typical Configuration<\/strong><\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">6 Low-E + 16A + 6 Clear<\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">6 Low-E + 12A + 6 E60<\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">6 Low-E + 12A + 15 EI30<\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">6 Low-E + 16A + 24 EI60<\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">8 Low-E + 16A + 45 EI120<\/td>\n<\/tr>\n<tr style=\"background-color:#f8fafc;\">\n<td style=\"padding:12px; border:1px solid #e2e8f0;\"><strong>Total Thickness<\/strong><\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">28 mm<\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">24 mm<\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">33 mm<\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">46 mm<\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">69 mm<\/td>\n<\/tr>\n<tr style=\"background-color:#ffffff;\">\n<td style=\"padding:12px; border:1px solid #e2e8f0;\"><strong>Center U-Value (W\/m&sup2;K)<\/strong><\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">1.1 &#8211; 1.4<\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">1.2 &#8211; 1.5<\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">1.1 &#8211; 1.3<\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">1.0 &#8211; 1.2<\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">0.8 &#8211; 1.0<\/td>\n<\/tr>\n<tr style=\"background-color:#f8fafc;\">\n<td style=\"padding:12px; border:1px solid #e2e8f0;\"><strong>Solar Heat Gain (SHGC \/ g)<\/strong><\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">0.28 &#8211; 0.42<\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">0.30 &#8211; 0.45<\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">0.28 &#8211; 0.40<\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">0.26 &#8211; 0.38<\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">0.24 &#8211; 0.35<\/td>\n<\/tr>\n<tr style=\"background-color:#ffffff;\">\n<td style=\"padding:12px; border:1px solid #e2e8f0;\"><strong>Light Transmittance (VLT)<\/strong><\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">65% &#8211; 78%<\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">70% &#8211; 80%<\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">68% &#8211; 76%<\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">62% &#8211; 72%<\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">55% &#8211; 65%<\/td>\n<\/tr>\n<tr style=\"background-color:#f8fafc;\">\n<td style=\"padding:12px; border:1px solid #e2e8f0;\"><strong>Sound Insulation (Rw \/ STC)<\/strong><\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">34 &#8211; 36 dB<\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">36 &#8211; 38 dB<\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">42 &#8211; 45 dB<\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">45 &#8211; 48 dB<\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">49 &#8211; 52 dB<\/td>\n<\/tr>\n<tr style=\"background-color:#ffffff;\">\n<td style=\"padding:12px; border:1px solid #e2e8f0;\"><strong>Fire Integrity (E)<\/strong><\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">0 min<\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">&ge; 60 min<\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">&ge; 30 min<\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">&ge; 60 min<\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">&ge; 120 min<\/td>\n<\/tr>\n<tr style=\"background-color:#f8fafc;\">\n<td style=\"padding:12px; border:1px solid #e2e8f0;\"><strong>Thermal Insulation (I)<\/strong><\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">0 min<\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">0 min<\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">&ge; 30 min (&Delta;T&le;140&deg;C)<\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">&ge; 60 min (&Delta;T&le;140&deg;C)<\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">&ge; 120 min (&Delta;T&le;140&deg;C)<\/td>\n<\/tr>\n<tr style=\"background-color:#ffffff;\">\n<td style=\"padding:12px; border:1px solid #e2e8f0;\"><strong>Max Dimension<\/strong><\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">3300 &times; 8000 mm<\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">2400 &times; 4200 mm<\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">2400 &times; 3600 mm<\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">2200 &times; 3200 mm<\/td>\n<td style=\"padding:12px; border:1px solid #e2e8f0;\">1800 &times; 3000 mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<hr style=\"border: 0; height: 1px; background: #e2e8f0; margin: 35px 0;\" \/>\n<h2 style=\"color: #0f172a; margin-top: 30px;\">3. International Testing Standards &amp; Facade Code Compliance<\/h2>\n<p style=\"line-height: 1.8; color: #333;\">When specifying exterior fire-rated glazing for international facade and curtain wall packages, compliance with regional building codes and rigorous full-assembly testing is mandatory:<\/p>\n<h3 style=\"color: #1e293b;\">1. European Standards (EN Norms)<\/h3>\n<ul style=\"line-height: 1.8; color: #333; padding-left: 20px;\">\n<li><strong>EN 1364-3 (Curtain Walling &#8211; Full Configuration):<\/strong> Evaluates the complete fire resistance of non-loadbearing curtain wall systems under external and internal fire exposure scenarios.<\/li>\n<li><strong>EN 1364-1 &amp; EN 1634-1:<\/strong> Fire testing for glazed partitions, windows, and doorsets.<\/li>\n<li><strong>EN 1279 Parts 1&ndash;6:<\/strong> Strict durability and moisture penetration standards for insulating glass units, verifying long-term gas leakage rates &lt;1%\/year.<\/li>\n<li><strong>Classification:<\/strong> Class E (Integrity), Class EW (Radiation control &le;15 kW\/m&sup2;), Class EI (Full thermal insulation &Delta;T&le;140&deg;C).<\/li>\n<\/ul>\n<h3 style=\"color: #1e293b;\">2. North American Standards (ASTM \/ UL \/ NFPA)<\/h3>\n<ul style=\"line-height: 1.8; color: #333; padding-left: 20px;\">\n<li><strong>ASTM E119 \/ UL 263 \/ NFPA 251:<\/strong> Standard test methods for fire tests of building construction and materials (Fire-Resistance-Rated Glazing).<\/li>\n<li><strong>Mandatory Hose Stream Test:<\/strong> Following fire furnace exposure, the hot assembly is immediately subjected to a high-pressure solid water stream (30 psi for 1-hour, 45 psi for 2-hour tests). Shenying fire-rated DGUs are engineered to resist severe thermal shock without breach.<\/li>\n<li><strong>ASTM E283, E330, E331:<\/strong> Verification of air infiltration, structural wind load performance, and static water penetration resistance for exterior building envelopes.<\/li>\n<\/ul>\n<h3 style=\"color: #1e293b;\">3. British Standards (BS 476)<\/h3>\n<ul style=\"line-height: 1.8; color: #333; padding-left: 20px;\">\n<li><strong>BS 476: Part 20 &amp; Part 22:<\/strong> Fire resistance testing of non-loadbearing elements of construction, widely referenced in the Middle East, Southeast Asia, and UK\/Commonwealth territories.<\/li>\n<\/ul>\n<hr style=\"border: 0; height: 1px; background: #e2e8f0; margin: 35px 0;\" \/>\n<h2 style=\"color: #0f172a; margin-top: 30px;\">4. Architectural Application Scenarios in Commercial Facades<\/h2>\n<figure style=\"margin: 35px 0; text-align: center;\">\n  <img decoding=\"async\" src=\"https:\/\/shenyingfireglass.com\/wp-content\/uploads\/2026\/11\/img-mvz0691b-8dd4e7f7.png\" alt=\"Modern Commercial Building Facade with Fire-Rated Insulated Glass Curtain Wall System\" style=\"max-width: 100%; height: auto; border-radius: 8px; box-shadow: 0 6px 20px rgba(0,0,0,0.12); border: 1px solid #e2e8f0;\" \/><figcaption style=\"margin-top: 12px; font-size: 0.92em; color: #64748b; font-style: italic;\">Figure 2: Premium corporate headquarters facade featuring large-format fire-rated double-glazed curtain wall units, delivering expansive daylighting and thermal efficiency while complying with life safety fire separation zones.<\/figcaption><\/figure>\n<p style=\"line-height: 1.8; color: #333;\">Fire-rated DGU \/ IGU assemblies are widely specified across critical facade and envelope zones in modern architectural developments:<\/p>\n<ul style=\"line-height: 1.8; color: #333; padding-left: 20px;\">\n<li style=\"margin-bottom: 12px;\"><strong>High-Rise Curtain Walls &amp; Spandrel Fire Barriers:<\/strong> Building codes require vertical fire containment between consecutive floors to prevent exterior fire leap-frogging. Fire-rated DGUs provide seamless vision-to-spandrel aesthetics with certified 60-to-120 minute fire stopping.<\/li>\n<li style=\"margin-bottom: 12px;\"><strong>Property Boundary Line \/ Zero-Lot-Line Facades:<\/strong> When adjacent commercial towers or residential developments are built in close proximity, exterior walls require fire-resistance-rated glazing to prevent building-to-building radiative ignition.<\/li>\n<li style=\"margin-bottom: 12px;\"><strong>Atrium Skylights &amp; Sloped Overhead Glazing:<\/strong> Combining laminated impact safety, solar heat rejection, and overhead fire barrier performance for busy shopping malls, airport terminals, and transit hubs.<\/li>\n<li style=\"margin-bottom: 12px;\"><strong>Hotel &amp; Residential Balcony \/ Escape Corridor Enclosures:<\/strong> Exterior walkways and balcony exit routes require acoustic dampening against urban traffic noise, solar protection, and Class EI fire shielding to ensure safe tenant evacuation.<\/li>\n<\/ul>\n<hr style=\"border: 0; height: 1px; background: #e2e8f0; margin: 35px 0;\" \/>\n<h2 style=\"color: #0f172a; margin-top: 30px;\">5. Sourcing &amp; Specification Checklist for Overseas B2B Buyers<\/h2>\n<p style=\"line-height: 1.8; color: #333;\">When requesting engineering quotations or issuing RFQs for Fire-Rated DGU\/IGU products, ensure the following technical parameters are specified:<\/p>\n<ol style=\"line-height: 1.8; color: #333; padding-left: 20px;\">\n<li style=\"margin-bottom: 10px;\"><strong>Fire Directionality:<\/strong> Specify whether fire resistance is required from the interior, exterior, or both directions (symmetrical vs. asymmetrical configuration).<\/li>\n<li style=\"margin-bottom: 10px;\"><strong>Coating Position &amp; Optical Specs:<\/strong> Clarify Low-E coating requirements (Surface #2 for maximum solar control), target U-value, SHGC, and Visible Light Transmittance (VLT).<\/li>\n<li style=\"margin-bottom: 10px;\"><strong>Cavity Width &amp; Gas Filling:<\/strong> Standard spacer widths include 12A, 16A, and 20A. Request &ge;90% Argon gas with warm-edge composite spacers for optimal thermal break performance.<\/li>\n<li style=\"margin-bottom: 10px;\"><strong>Frame Compatibility:<\/strong> Fire-rated glass units must be paired with certified thermally broken fire-rated steel or composite aluminum framing profiles. Shenying provides complete glass-and-frame turnkey packages.<\/li>\n<li style=\"margin-bottom: 10px;\"><strong>Seaworthy Export Crating:<\/strong> Insist on heavy-duty, fumigation-free plywood crates with anti-vibration rubber pads, corner caps, vacuum desiccant packs, and moisture-proof plastic wrap.<\/li>\n<\/ol>\n<hr style=\"border: 0; height: 1px; background: #e2e8f0; margin: 35px 0;\" \/>\n<h2 style=\"color: #0f172a; margin-top: 30px;\">6. Why Partner with Jinan Shenying Fire Glass Doors &amp; Windows<\/h2>\n<p style=\"line-height: 1.8; color: #333;\"><strong>Jinan Shenying Fire-Resistant Glass, Doors and Windows Co., Ltd.<\/strong> is an internationally recognized specialist manufacturer established in 2014. Operating automated CNC cutting, precision laminating autoclaves, robotic double-glazing lines, and in-house fire testing furnaces, Shenying delivers custom facade solutions globally.<\/p>\n<ul style=\"line-height: 1.8; color: #333; padding-left: 20px;\">\n<li><strong>Certified Performance:<\/strong> Full compliance with EN 1364, EN 1634, UL 263, ASTM E119, and BS 476 standards.<\/li>\n<li><strong>Advanced Low-E Integration:<\/strong> Precision pairing of world-class Low-E coatings with cutting-edge nano-silicon intumescent fire barriers.<\/li>\n<li><strong>Zero Delamination &amp; High Weatherability:<\/strong> Advanced edge-sealing technology engineered for extreme climates from -40&deg;C to +80&deg;C.<\/li>\n<li><strong>Global Project Track Record:<\/strong> Exported to facade contractors and distributors in over 100 countries across Europe, North America, the Middle East, and Australia.<\/li>\n<\/ul>\n<div style=\"background: linear-gradient(135deg, #0f172a 0%, #1e293b 100%); color: #ffffff; padding: 32px; border-radius: 8px; margin: 35px 0; text-align: center;\">\n<h3 style=\"color: #ffffff; margin-top: 0; font-size: 1.45em;\">Request a Facade Engineering Consultation &amp; Factory Quotation<\/h3>\n<p style=\"color: #cbd5e1; max-width: 680px; margin: 15px auto; font-size: 1.05em; line-height: 1.6;\">Are you engineering an exterior facade or curtain wall project that requires both energy-saving Low-E glazing and certified Class EI fire containment? Contact our technical engineering team for custom glass build-ups, structural calculations, and competitive FOB\/CIF project pricing.<\/p>\n<div style=\"margin-top: 25px;\">\n    <a href=\"https:\/\/shenyingfireglass.com\/contact-us\/\" style=\"display: inline-block; background-color: #0284c7; color: #ffffff; padding: 12px 28px; border-radius: 6px; text-decoration: none; font-weight: bold; font-size: 1.05em; margin-right: 15px;\">Contact Facade Engineers<\/a><br \/>\n    <a href=\"https:\/\/wa.me\/8618668985635\" target=\"_blank\" style=\"display: inline-block; background-color: #22c55e; color: #ffffff; padding: 12px 28px; border-radius: 6px; text-decoration: none; font-weight: bold; font-size: 1.05em;\">Chat on WhatsApp<\/a>\n  <\/div>\n<p style=\"margin-top: 22px; font-size: 0.9em; color: #94a3b8;\">\n    <strong>Email:<\/strong> sales@shenyingfireglass.com &nbsp;|&nbsp; <strong>WhatsApp\/Phone:<\/strong> +86 186 6898 5635 &nbsp;|&nbsp; <strong>Headquarters:<\/strong> Jinan, Shandong, China\n  <\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>D\u00e9couvrez comment le vitrage isolant \u00e0 double vitrage r\u00e9sistant au feu (DGU\/IGU r\u00e9sistant au feu) allie isolation thermique (coefficient U pouvant descendre jusqu\u2019\u00e0 1,1 W\/m\u00b2K), des rev\u00eatements Low-E de contr\u00f4le solaire et une r\u00e9sistance au feu certifi\u00e9e de classe EI30 \u00e0 EI120 pour les fa\u00e7ades commerciales modernes et les murs-rideaux de Jinan Shenying.<\/p>","protected":false},"author":1,"featured_media":10980,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"","_seopress_redirections_param":"","_seopress_redirections_type":0,"_seopress_analysis_target_kw":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[23],"tags":[],"class_list":["post-10982","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"_links":{"self":[{"href":"https:\/\/shenyingfireglass.com\/fr\/wp-json\/wp\/v2\/posts\/10982","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/shenyingfireglass.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/shenyingfireglass.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/shenyingfireglass.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/shenyingfireglass.com\/fr\/wp-json\/wp\/v2\/comments?post=10982"}],"version-history":[{"count":0,"href":"https:\/\/shenyingfireglass.com\/fr\/wp-json\/wp\/v2\/posts\/10982\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shenyingfireglass.com\/fr\/wp-json\/wp\/v2\/media\/10980"}],"wp:attachment":[{"href":"https:\/\/shenyingfireglass.com\/fr\/wp-json\/wp\/v2\/media?parent=10982"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/shenyingfireglass.com\/fr\/wp-json\/wp\/v2\/categories?post=10982"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/shenyingfireglass.com\/fr\/wp-json\/wp\/v2\/tags?post=10982"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}